The OBS-3+ is a submersible turbidity probe that has sideways-facing optics. It uses OBS technology to measure suspended solids and turbidity for applications ranging from water quality in freshwater rivers and streams to sediment transport and dredge monitoring. Campbell Scientific data loggers measure the OBS-3+ probe's output and calculate turbidity.
Read MoreThe OBS-3+ uses its sideways-facing optics to emit a near-infrared light into the water. It then measures the light that bounces back from the water’s suspended particles.
If an obstruction is in the emitted light’s range, the light will scatter back and the turbidity reading will be too high. This probe's sideways-facing optics avoids obstructions above and below the probe. The OBS300 is available for locations that have obstructions around the sides of the probe.
OBS® is a registered trademark of Campbell Scientific.
Range |
|
Maximum Submersion Depth |
|
Concentration Accuracy |
|
Maximum Concentration Range |
|
Operating Temperature Range | 0° to 40°C |
Drift over Time | < 2% per year |
Maximum Data Rate | 10 Hz |
Minimum Warm-up Time | 2 s |
Infrared Wavelength | 850 nm ±5 nm |
Daylight Rejection | -28 dB (re: 48 mW/cm-2) |
Optical Power | 2000 µW |
Turbidity Accuracy | 2% of reading or 0.5 NTU (whichever is larger) |
Housing Material | 316 stainless steel or titanium |
Connector | MCBH-5-FS, wet-pluggable |
Diameter | 2.5 cm (0.98 in.) |
Height | 14.7 cm (5.79 in.) |
Weight | 181.4 g (0.4 lb) |
-2.5 Output Option |
|
Output Voltage | 0 to 2.5 V (over selected NTU range) |
Supply Voltage | 5 to 15 Vdc |
Current Drain | 15 mA |
-5 Output Option |
|
Output Voltage | 0 to 5 V (over selected NTU range) |
Supply Voltage | 5 to 15 Vdc |
Current Drain | 15 mA |
-20 Output Option |
|
Output Voltage | 4 to 20 mA (over selected NTU range) |
Supply Voltage | 9 to 15 Vdc |
Current Drain | 45 mA |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR1000 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR800 (retired) | ||
CR800 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR850 (retired) | ||
CR850 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) | ||
CR9000X (retired) |
Number of FAQs related to OBS-3+: 4
Expand AllCollapse All
It used to be that NTUs were the unit for all turbidity sensors. In 2007, an ASTM committee formed and established different units for each category of turbidity sensor technology, and there are many. Backscatter sensors such as the OBS-3+ and the OBS501 have units of FBU (Formazin Backscatter Units), whereas ISO 7027 side-scatter sensors have units of FNU (Formazin Nephelometric Units). The side-scatter OBS501 and the ClariVue™ sensors are part of this category. While sensors of different technical designs can be calibrated and measure Formazin the same, they will not make the same measurement in natural waters where size, shape, color, reflectivity, etc., of the particles vary. The ClariVue™ sensor measurements will not match the OBS-3+ measurements in natural waters.
The most significant difference between backscatter and side-scatter measurements is the sample volume. A backscatter sensor has a much larger sample volume that helps measure higher turbidity values. The smaller sample volume of side-scatter sensors works better at lower turbidities.
No. A datalogger is necessary.
This depends on the turbidity of the water. In very clear water exposed to direct sunlight, up to 18 in. of water may be needed to prevent the sun from affecting the readings. Less sunlight penetrates more turbid water, which means the sensor would not need to be positioned as deeply. If the target water is clear and shallow, it may be necessary to construct a canopy above the water to shadow the monitoring site.
In addition, the sensor must be positioned in the water so that nothing obstructs its field of view. In very clear water, this may require an 18 in. standoff.