RETIRED ›
This product is no longer available and has been replaced by: CS106. Some accessories, replacement parts, or services may still be available.
CS105 Vaisala PTB101B Barometer
Services Available
Repair No
Calibration Yes
Free Support No

Overview

The CS105 measured barometric pressure for the range of 600 to 1060 mb (approximately sea level to 12,000 feet). A 12 V switching circuit was included in the sensor; a datalogger control port was used to control 12 Vdc power to the sensor, reducing power consumption. A sensor warm-up time of up to 1 second was recommended.

Images


Specifications

  • Dimensions: 2.4" x 2.4" x 0.8" (6.1 x 6.1 x 2.0 cm)
  • Accuracy: ±0.5 mb @ +20°C
  • Temperature Range: -40° to 60°C

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR800 (retired)
CR800 (retired)
CR800 (retired)
CR850 (retired)
CR850 (retired)
CR850 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Data Logger Considerations

A 2.5-ft cable is supplied with the sensor for connection to the data logger. The cable connects to a control port, single-ended analog input terminal, 12 V power terminal, and ground terminal on the data logger.

Mounting

The CS105 is typically mounted next to the data logger inside an ENC12/14 or larger enclosure. The very small ENC100 is available for housing the CS105 separately, in its own enclosure.


Related FAQs

Number of FAQs related to CS105: 2

  1. The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a datalogger. For other sensors, the calibration sheet is a pass/fail report.

  2. This depends on the information contained in the calibration sheet:

    • If the calibration sheet contains coefficient information, Campbell Scientific keeps a copy, and a replacement copy can be requested.
    • If the calibration sheet does not contain coefficients, Campbell Scientific does not keep a copy. It may be possible to contact the original manufacturer for a replacement copy.

Case Studies

Delaware: Environmental Observing System
The Delaware Environmental Observing System (DEOS) is a real-time system dedicated to monitoring environmental conditions......read more
Austin College Weather Station
The Austin College Weather Station (ACWX) is located on Austin College's Sneed Environmental Research Area,......read more
Utah Energy Industry: Air Quality and Met Monitoring
The past few years have seen a scramble within the power industry to use more......read more
Argentina: Hydro-Meteorological Network
Controlling the water level of the Neuquen, Limay, and Negro rivers of Argentina is a......read more