RETIRED ›
This product is no longer available and has been replaced by: CS11-L. Some accessories, replacement parts, or services may still be available.
CS10-L Current Transducer
Services Available
Repair No
Calibration No
Free Support No

Overview

The CS10 monitors ac current along an electrical wire for the range of 0.15 A to 200 A. It outputs a millivolt signal that many of our dataloggers can directly measure.

Read More

Benefits and Features

  • Ideal applications include motor or generator load conditions, efficiency studies, intermittent fault detection, and rough submetering
  • No direct electrical connection to the electrical system

Images

Technical Description

The CS10 uses CR Magnetic's CR8459 Current Transformer to detect the ac current along an electrical wire using the magnetic field that is generated by that current. The CS10 is external to the wire jacket and has no direct electrical connection to the system.

The CS10 is recommended for measurements that do not require high accuracy, such as motor or generator load condition monitoring, efficiency studies, intermittent fault detection, and rough submetering.

Specifications

Measurement Range 0.15 to 200 A
Frequency 50 and 60 Hz
Insulation Resistance 100 MΩ (@ 500 Vdc)
High Potential 2000 V
Rated Current 200 A
Accuracy with 10 Ω Maximum Burden (resistive) Typically ±5% of actual value (with provided multiplier)
Operating Temperature Range -25° to +55°C
Case Material Polypropylene resin
Construction Epoxy encapsulated
Outer Diameter 4.8 cm (1.89 in.)
Inner Diameter 1.9 cm (0.75 in.)
Height 1.7 cm (0.67 in.)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR3000 (retired)
CR5000 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR800 (retired)
CR800 (retired)
CR800 (retired)
CR850 (retired)
CR850 (retired)
CR850 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Related FAQs

Number of FAQs related to CS10-L: 4

Expand AllCollapse All

  1. Yes. Three CS10-L sensors can be connected to a datalogger to measure the amperage on each of three phases.
  2. No. The CS10-L is an ac-only sensor.
  3. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field on the product’s Ordering tab. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  4. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a datalogger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact an application engineer at Campbell Scientific for assistance.