This high-performance anti-alias filter module can be used in either the CR9000X or CR9000 measurement and control system. The CR9052DC module measures accelerometers, strain gages, and microphones.

The CR9052DC includes six anti-aliased analog measurement channels with differential input ranges from ±20 mV to ±5 V. Each of the six channels has its own programmable-gain instrumentation amplifier, presampling analog filter, and sigma-delta analog-to-digital converter. An on-board digital signal processor provides real-time, programmable anti-alias filtering and down-sampling (decimation) before passing the results to the datalogger’s main processor.

Read More

Benefits and Features

  • Can be added to or removed from CR9000X to support changing measurement needs
  • Includes CR9052EC, which disconnects sensors easily so the CR9000X can be moved from location to location

Images

Technical Description

The CR9052DC is a high-performance anti-alias filter module for the CR9000X-series and CR9000-series dataloggers. It is used to measure accelerometers, strain gages, and microphones.

The CR9052DC includes six anti-aliased analog channels with differential input ranges from ±20 mV to ±5 V. Each of the six channels has its own programmable-gain instrumentation amplifier, pre-sampling analog filter, and sigma-delta analog-to-digital converter. An on-board digital signal processor provides real-time, programmable anti-alias filtering and down-sampling (decimation) before passing the results to the datalogger’s main processor.

The CR9052DC includes one CR9052EC easy connector module. Easy connector modules allow sensor wiring to remain connected while the input module’s measurement electronics and the rest of the datalogger system are used elsewhere. Additional CR9052ECs are purchased as a separate line item.

Specifications

-NOTE- Note: Additional specifications are listed in the CR9052IEPE and CR9052DC brochure.
Operating Temperature -40° to +70°C
Analog Channels 6 differential
Excitation Channels 6
Overvoltage Protection on All Inputs/Outputs +50 V, -40 V
Differential Accuracy
  • ±0.03% of reading (gain)
  • ±0.03% of full-scale input range (offset)
Current Drain (at 12 V input) 500 mA + 1.5*[Iex] where Iex is the sum of excitation currents provided by all channels
Dimensions 23.3 x 12.4 x 2.5 cm (9.2 x 4.9 x 1 in.)
Weight 0.5 kg (1 lb)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Listed Under