41003-5A 10-Plate Solar Radiation Shield with Band Clamp

Overview

The 41003-5A, manufactured by R. M. Young, is a naturally aspirated 10-plate radiation shield. Its louvered construction allows air to pass freely through the shield, keeping the probe at or near ambient temperature. The shield's white color reflects solar radiation. 

Read More

Benefits and Features

  • Naturally shades and protects the sensor

Images

Technical Description

The 41003-5A 10-Plate Gill Radiation Shield is typically used with an LW110 to house its HC2S3 Temperature and RH probe; the hex plug required to mount the HC2S3 in the shield is shipped with the sensor.

The 41003-5A can also house a 43347, 107, 108, 109, or HMP60 probe. The HMP45C and several other retired sensors are also compatible. Refer to the Compatibility tab for the hardware required to mount the above sensors in the shield.

Specifications

Construction UV-stabilized white thermoplastic plates, aluminum mounting bracket
Plate Diameter 11.9 cm (4.7 in.)
Height 20.3 cm (8.0 in.)
Weight 590 g (1.3 lb)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Sensors

Product Compatible Note
109-L The 41322 adapter is required to install a 109 probe.
CS215-L (retired)
HC2S3-L (retired) The 27731 hex plug is required to mount the HC2S3 in the 41003-5A.

Miscellaneous

Product Compatible Note
107-L The 41322 adapter is required to install a 107 probe.
108-L The 41322 adapter is required to install a 108 probe.
43347-L The 27251 hex plug is required to secure the 43347 RTD into the radiation shield's base.
CS500-L (retired) For the CS500, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the CS500 in a higher part of the shield; this configuration also requires the #18278 cable.
HMP155A-L
HMP45C-L (retired) The 27251 hex plug is required to mount an HMP45C in the 41003-5A.
HMP50-L (retired) For the HMP50, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP50 in a higher part of the shield; this configuration also requires the #18278 cable.
HMP60-L For the HMP60, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP60 in a higher part of the shield; this configuration also requires the #18278 cable.

Additional Compatibility Information

The 41003-5A attaches to a CM500-series pole or a user-supplied 2 in. IPS pole.

Related FAQs

Number of FAQs related to 41003-5A: 1

  1. To measure ambient temperature and relative humidity (RH), mount the HC2S3-L probe inside a 41003-5 or 41003-5A 10-Plate Radiation Shield. The 27731 hex plug is shipped with the HC2S3-L so that it can be used with older 10-plate radiation shield models. The 6-plate radiation shield (pn 41303-5A) cannot be used with the HC2S3-L.