Added support for a new battery type, type 4 "LiFePO4".
Modified the charge algorithm when LiFePO4 battery is used. The battery will charge as normal until (Qloss < 0.1*battery capacity) AND (battery current < 0.5). Lithium batteries aren’t supposed to be trickle charged; this algorithm takes care of that. When this condition is met for 20 consecutive seconds, we stop trying to charge the battery for 5 minutes, after that 5 minutes, we start trying to charge again, until the condition is met for 20 consecutive seconds and so on.
Added SDI-12 and terminal commands to force a watchdog reset. The SDI-12 command is aXWD! where a is the SDI-12 address of the device.
×
Cookie Settings
This website uses cookies in order to offer you the most relevant information. Please accept cookies for optimal performance.
Cookies expire 30 days from acceptance.
Please note that we also leverage third-party tools, such as Google Analytics, which may use cookies to collect information about your browsing activities. We cannot block these cookies, but we ensure that any third-party tools we use are GDPR-compliant and do not collect any personally identifiable information.