TE525MM-LC Texas Electronics Rain Gage 0.1 mm Tip with 9.6 in. Orifice
Services Available

Overview

The TE525MM-LC is a tipping-bucket rain gage that measures in increments of 0.1 mm and has a funnel diameter of 9.66 in. (24.5 cm). The TE525MM-LC funnels precipitation into a bucket mechanism that tips and actuates a switch. The momentary switch closure is counted by the pulse-counting circuitry of any of the Campbell Scientific data loggers. The cable on this version of the TE525MM has a connector rather than the standard pigtails. The connector attaches to the MetData1 Weather Station or CS110 Electric Field Meter.

Read More

Images

Technical Description

The TE525MM-LC measures rainfall in metric units rather than US units.  The cable on this version of the TE525MM Tipping Bucket Rain Gage has a connector rather than the standard pigtails. The connector attaches to the MetData1 Weather Station or CS110 Electric Field Meter. 

The TE525MM-LC measures rainfall in 0.1 mm increments. It funnels precipitation into a bucket mechanism that tips when filled to a calibrated level.

Specifications

  • Sensor type: Tipping bucket/magnetic reed switch
  • Material: Anodized aluminum
  • Resolution: 1 tip
  • Volume per Tip: 0.16 fl. oz/tip (4.73 ml/tip)
  • Rainfall per Tip: 0.1 mm (0.004 inches)
  • Accuracy
    • Up to 10 mm/hr: ±1%
    • 10 to 20 mm/hr: +0, -3%
    • 20 to 30 mm/hr: +0, -5%

Compatibility

The connector can be attached to the CS110 Electric Field Meter or MetData1 Weather Station. The CS110 has a CR1000 and the MetData1 has an on-board CR10X.


Related FAQs

Number of FAQs related to TE525MM-LC: 4

Expand AllCollapse All

  1. The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a datalogger. For other sensors, the calibration sheet is a pass/fail report.

  2. This depends on the information contained in the calibration sheet:

    • If the calibration sheet contains coefficient information, Campbell Scientific keeps a copy, and a replacement copy can be requested.
    • If the calibration sheet does not contain coefficients, Campbell Scientific does not keep a copy. It may be possible to contact the original manufacturer for a replacement copy.
  3. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field on the product’s Ordering tab. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  4. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a datalogger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact an application engineer at Campbell Scientific for assistance.