Precipitation / TB4-LC
RETIRED ›
This product is no longer available. Some accessories, replacement parts, or services may still be available.
TB4-LC Rain Gage for CS110 or MetData1
Services Available
Repair No
Calibration No
Free Support No

Overview

The TB4-LC, manufactured by Hydrological Services, has an 8" orifice and measures rainfall in 0.01" increments. It contains an internal siphon mechanism that causes rain to flow at a steady rate to the tipping bucket mechanism (regardless of intensity).

Read More

Benefits and Features

  • Accuracy is ±3 percent at high precipitation rates of 500 mm/hr

Images

Technical Description

The TB4 funnels precipitation into a bucket mechanism that tips when filled to its calibrated level. Each tip is marked by a dual reed switch closure that is recorded by a data logger pulse count channel. After measurement, the water drains through two orifices (accepts 12 mm tubing) in the base, allowing the measured water to be collected in a separate container.

The TB4 contains an internal siphon mechanism that causes rain to flow at a steady rate to the tipping bucket mechanism (regardless of intensity). The siphon allows the sensor to make accurate measurements over a range of 0 to 700 mm per hour.

 

Specifications

Sensor Type Tipping bucket with siphon
Accuracy
  • ±2% @ < 250 mm/hr (9.8 in./hr)
  • ±3% @ 250 to 500 mm/hr (9.8 to 19.7 in./hr)
Resolution 0.01 in. (0.254 mm)
Measurement Range 0 to 700 mm/hr (0 to 27.6 in./hr)
Temperature Range 0° to 70°C
Humidity 0 to 100%
Cable Two-conductor shielded
Orifice Diameter 20 cm (7.9 in.)
Drain Tube Size Both filters accept 12 mm (0.47 in.) inner diameter tubing.
Height 33 cm (13 in.)
Weight 2 kg (4.4 lb) with 7.62-m (25-ft) cable

Related FAQs

Number of FAQs related to TB4-LC: 2

  1. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field on the product’s Ordering tab. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  2. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a datalogger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact an application engineer at Campbell Scientific for assistance.