Services Available | |
---|---|
Repair | Yes |
Calibration | Yes |
Free Support | Yes |
The PVS4100D is a deluxe ac-powered only water sampler that deposits its water samples into 24 containers. It uses a bigger sampler pump, allowing it to support the fastest sampling rates and longest sampling distances. The PVS4100D includes a programmable controller with 16-key intuitive touch pad. The controller can accept a pulse input (e.g., rain gage), a 4 to 20 mA signal (e.g., flow meter), or initiate a sample on a timed basis. The sampler can also be interfaced with our dataloggers to measure a variety of sensors, as well as control the sampler based on time, event, or measured conditions.
Read MoreThe PVS4100D is designed for ac applications only. The PVS4100D uses an external vacuum pump to draw water through intake tubing, instead of the traditional peristaltic pump that induce flow by squeezing flexible tubing. Advantages of the vacuum pump method include faster sampling rates, longer sampling distances, and less maintenance. Because the vacuum method disturbs the water samples less, they better represent the original water solution, especially if the solution has high concentrations of suspended solids. To prevent cross contamination, the sampler use air pressure (up to 28 psi) to purge the tubing of excess water.
The enclosure of the PVS4100D is a molded medium-density linear polyethylene, designed to handle tough environmental challenges and weathering. Its hub has an insulated ring and a cavity for crushed ice, giving more control over the temperature of the sample.
Enclosure | Molded medium-density linear polyethylene, three-piece construction and stainless-steel fittings |
Integral Battery | 115 Vac/60 Hz or 12 Vdc |
Cooling System | Insulated container wall cavity space for ice |
Body Case Diameter | 42.8 cm (16.85 in.) |
Height |
|
Sampler Weight | 11.8 kg (26 lb) without battery |
Battery Weight | 6.3 kg (14 lb) |
Vacuum System |
|
Pinch Valve | Fixed – normally open |
Purge Cycle | Adjustable from 1 to 99 s |
Suction Cycle | Variable (Adjusts automatically to double the input value of the purge time setting or until liquid contacts level electrode in metering chamber.) |
Sample Volume | Adjustable from 50 to 500 cc or Adjustable from 500 to 1000 cc |
Horizontal Transport Velocity |
|
Maximum Horizontal Transport Distance | 76.2 m (250 ft) |
Metering Chamber Cover | Nylon |
Volume Control Tube | 316 stainless steel |
Metering Chamber Level Electrode | 316 stainless steel |
Discharge Hose Material | Latex |
Controller |
|
Display | 2 x 16 character backlit LCD |
Touchpad | 6 key (with multi-level menu) |
Start Delay | Disabled, Time/Day, Pulse Count, 4 to 20 mA (0 to 100 pulses/min.), External Contact, Level Control |
Sample Initiation | Disabled, Time/Day, Pulse Count, 4 to 20 mA (0 to 100 pulses/min.), External Contact, Level Control |
Program Type | Composite, Multi-Composite, Consecutive, Daily Cycle, Timed Step |
Clock | Real-time clock and operating system |
Direct Function Keys | Manual sample, Manual purge, Manual bottle advance, Restart |
Switches | Controller on/off (SPST toggle) |
Available Displays | Real-time clock, process timing, process totals, pulse counting, event response, multilevel descriptions, flashing prompts, diagnostics |
Automatic Displays | Container Full, Fault, Power Interrupt (program resumed), Alternating Time Stamp, Cycle(s) abandoned |
The PVS4100D includes a programmable controller with 16-key intuitive touch pad. The controller can accept a pulse input (for example, rain gage), a 4 to 20 mA signal (for example, flow meter), or initiate a sample on a timed basis. The sampler can also be interfaced with our data loggers. Our data loggers can measure nearly any turbidity, water level, or hydrometeorological sensor, as well as control the sampler based on time, event, or measured conditions.