Overview

The PVS4100D is a deluxe ac-powered only water sampler that deposits its water samples into 24 containers. It uses a bigger sampler pump, allowing it to support the fastest sampling rates and longest sampling distances. The PVS4100D includes a programmable controller with 16-key intuitive touch pad. The controller can accept a pulse input (e.g., rain gage), a 4 to 20 mA signal (e.g., flow meter), or initiate a sample on a timed basis. The sampler can also be interfaced with our dataloggers to measure a variety of sensors, as well as control the sampler based on time, event, or measured conditions.

Read More

Benefits and Features

  • Bigger pump allows it to support faster sampling rates and longer sampling distances
  • Side handles for easy lifting (increases diameter)
  • Handcart available for easy transport
  • Stainless-steel suspension harness offered for sampling in sewer systems
  • Interfaces with Campbell Scientific data loggers for more measurement and control capabilities

Images

Technical Description

The PVS4100D is designed for ac applications only. The PVS4100D uses an external vacuum pump to draw water through intake tubing, instead of the traditional peristaltic pump that induce flow by squeezing flexible tubing. Advantages of the vacuum pump method include faster sampling rates, longer sampling distances, and less maintenance. Because the vacuum method disturbs the water samples less, they better represent the original water solution, especially if the solution has high concentrations of suspended solids. To prevent cross contamination, the sampler use air pressure (up to 28 psi) to purge the tubing of excess water.

The enclosure of the PVS4100D is a molded medium-density linear polyethylene, designed to handle tough environmental challenges and weathering. Its hub has an insulated ring and a cavity for crushed ice, giving more control over the temperature of the sample.

Specifications

Enclosure Molded medium-density linear polyethylene, three-piece construction and stainless-steel fittings
Integral Battery 115 Vac/60 Hz or 12 Vdc
Cooling System Insulated container wall cavity space for ice
Body Case Diameter 42.8 cm (16.85 in.)
Height
  • 80.9 cm (31.875 in.)
  • 96.2 cm (37.875 in.) with extended base
Sampler Weight 11.8 kg (26 lb) without battery
Battery Weight 6.3 kg (14 lb)

Vacuum System

Pinch Valve Fixed – normally open
Purge Cycle Adjustable from 1 to 99 s
Suction Cycle Variable (Adjusts automatically to double the input value of the purge time setting or until liquid contacts level electrode in metering chamber.)
Sample Volume Adjustable from 50 to 500 cc or Adjustable from 500 to 1000 cc
Horizontal Transport Velocity
  • minimum of 1.5 m/s (5 ft/s) at 30.5 m (100 ft)
  • > 0.8 m/s (2.5 ft/s) at 76.2 m (250 ft)
Maximum Horizontal Transport Distance 76.2 m (250 ft)
Metering Chamber Cover Nylon
Volume Control Tube 316 stainless steel
Metering Chamber Level Electrode 316 stainless steel
Discharge Hose Material Latex

Controller

Display 2 x 16 character backlit LCD
Touchpad 6 key (with multi-level menu)
Start Delay Disabled, Time/Day, Pulse Count, 4 to 20 mA (0 to 100 pulses/min.), External Contact, Level Control
Sample Initiation Disabled, Time/Day, Pulse Count, 4 to 20 mA (0 to 100 pulses/min.), External Contact, Level Control
Program Type Composite, Multi-Composite, Consecutive, Daily Cycle, Timed Step
Clock Real-time clock and operating system
Direct Function Keys Manual sample, Manual purge, Manual bottle advance, Restart
Switches Controller on/off (SPST toggle)
Available Displays Real-time clock, process timing, process totals, pulse counting, event response, multilevel descriptions, flashing prompts, diagnostics
Automatic Displays Container Full, Fault, Power Interrupt (program resumed), Alternating Time Stamp, Cycle(s) abandoned

Compatibility

Controller

The PVS4100D includes a programmable controller with 16-key intuitive touch pad. The controller can accept a pulse input (for example, rain gage), a 4 to 20 mA signal (for example, flow meter), or initiate a sample on a timed basis. The sampler can also be interfaced with our data loggers. Our data loggers can measure nearly any turbidity, water level, or hydrometeorological sensor, as well as control the sampler based on time, event, or measured conditions.