Ten Campbell Scientific CR10X data loggers were used to monitor movement during the repair of the UK's M2 Medway Bridge. The project required a jacking system to be installed at each of the 20 piers, transferring the deck loading from the bearings to allow the reconstruction of the bearing plinths. Each carriageway deck weighed around 1200 tons and once the load was transferred, the jacks were monitored to ensure settlement at any pier didn't exceed 2 mm. At each pier, a group of 10 jacks was linked to a single pump, a pressure transducer in a hydraulic circuit fitted to each pair of jacks with six linear transducers used to monitor the deck movement. The data loggers were set to trigger alarms and automatically call engineers via mobile phone if movement exceeded preset values.

Case Study Summary

Application

Bridge components monitored during reconstruction project

Location

near Medway Towns, Kent, England

Products Used

CR10X 

Measured Parameters

Hydraulic pressure, bridge movement

Controlled Devices

Alarms, Automated Voice Callout via Cellphone