HC2S3H-L Temperature and Relative Humidity Probe (High accuracy)
Services Available

Overview

The HC2-S3H is a high accuracy version of the HC2-S3. The HC2S3 is a rugged, accurate temperature and humidity probe that is ideal for long-term, unattended applications. The probe uses an advanced capacitive sensor to measure relative humidity. The probe includes a filter to protect the sensor from dust and particles, for superior performance and reliability.

Read More

Benefits and Features

  • Well-suited for long-term, unattended applications
  • Accurate and rugged
  • Compatible with all Campbell Scientific data loggers (including the CR200(X) series)

Images

Technical Description

The HC2S3 comes with a polyethylene filter that protects its sensor from fine dust and particles and minimizes water absorption and retention. Alternatively, a Teflon filter is available for marine environments. The response time is slower when using the Teflon filter.

Specifications

  • Electronics Operating Limits: -40° to +100°C
  • Storage Temperature: -50° to +100°C
  • Diameter: 15 mm (0.6 in.)
  • Length w/o connector: 85 mm (3.3 in.)
  • Length w/connector: 183 mm (7.25 in.)
  • Weight: 10 g (0.35 oz)
  • Filter: Polyethylene (standard) or Teflon (optional, ordered separately)
  • Current Consumption:
    < 4.3 mA @ 5 Vdc
    < 2.0 mA @ 12 Vdc
  • Supply Voltage: 5 to 24 Vdc
  • Startup Time: 1.5 s typicala
  • Maximum Startup Current:
    < 50 mA for 2 μs
  • Analog Outputs
    Offset at 0 V: ±3 mV (maximum)
    Deviation for Digital Signal:
    < ±1 mV (0.1°C, 0.1% R. H.)

Air Temperature

  • Temperature Sensor: PT100 RTD, IEC 751 1/3 Class B
  • Measurement Range: -40° to +60°C (default)b
  • Output Signal Range: 0 to 1 V
  • Accuracy at 23°C: ±0.1°C with standard configuration settings
  • Long Term Stability: < 0.1°C/year
  • Sensor Time Constant
    [63% step change (1 m/s air flow at sensor)]
    Standard PE Filter: ≤ 22 s
    Optional Teflon Filter: ≤ 30 s
  • Temperature Accuracy: see graph in manual

Relative Humidity

  • Sensor: ROTRONIC® Hygromer IN-1
  • Measurement Range: 0 to 100% RH, non-condensing
  • Output Signal Range: 0 to 1 Vdc
  • Long-Term Stability: < 1% RH per year
  • Response Time: Typical 10 s, 63% of a 35% to 80% RH step change (1 m/s air flow at sensor)
  • Accuracy at 23°C: ±0.5% RH with standard configuration settings
  • Sensor Time Constant
    [63% of a 35 to 80% RH step change (1 m/s air flow at sensor)]
    Standard PE Filter: ≤ 22 s
    Optional Teflon Filter: ≤ 30 s
  • RH Accuracy over Temperature: see graph in manual

a - The startup time is Rotronics specification. For programming, Campbell Scientific recommends a 2 s delay at 60°C, 3 s delay at 0°C, and 4 s delay at -40°C.

b - Air temperature measurement ranges from -50° to +100°C are possible; contact Campbell Scientific for more information.

Compatibility

Mounting

The HC2S3 should be housed in a 41003-5 10-plate naturally-aspirated solar radiation shield. This radiation shield mounts to a tripod or tower mast, crossarm, or user-supplied pole.

Datalogger Considerations

Compatible Contemporary Dataloggers

CR200(X) Series CR800/CR850 CR1000 CR3000 CR5000 CR7X CR9000X

Compatible Retired Dataloggers

CR500 CR510 CR10 CR10X 21X CR23X CR9000