Services Available | |
---|---|
Repair | Yes |
Calibration | No |
Free Support | Yes |
The CS215-PWS is a temperature and relative humidity probe with a special connector on the cable for attaching to a PWS100. It uses a Swiss-made digital humidity and temperature element that makes accurate and stable measurements. The CS215-PWS outputs an SDI-12 signal measurable by most Campbell Scientific dataloggers.
Read MoreFor this version of the CS215 Temperature and RH Probe, the cable has, instead of pigtails, a connector for attachment to the PWS100. Cable length is 1 meter.
The CS215 uses the Sensirion SHT75, a combined relative humidity and temperature element, to provide accurate, stable measurements. The Sensirion SHT75 element is field-replaceable, eliminating the downtime typically required for the recalibration process. The CS215 outputs an SDI-12 signal that's measurable by many Campbell Scientific dataloggers.
The CS215 should be housed in a solar radiation shield—typically the 41303-5A. The 41303-5A 6-plate naturally aspirated shield attaches to a mast, crossarm, or tower leg.
Sensing Element | Sensirion SHT75 |
Communication Standard | SDI-12 V1.3 (responds to a subset of commands) |
Supply Voltage | 6 to 16 Vdc (typically powered by data logger’s 12 V supply) |
Typical Current Drain |
|
EMC Compliance | Tested and conforms to IEC61326:2002. |
Operating Temperature Range | -40° to +70°C |
Diameter |
|
Probe Length | 18.0 cm (7.1 in.) including strain relief |
Cable Length | 10 m (33 ft) |
Weight | 350 g (12.3 oz) with 10-m (33-ft) cable |
Relative Humidity |
|
Measurement Range | 0 to 100% RH (-20° to +60°C) |
Output Resolution | 0.03% RH |
Accuracy |
|
Short-Term Hysteresis | < 1% RH |
Temperature Dependence | Better than ±2% (-20° to +60°C) |
Typical Stability | ±1.0% per year |
Response Time with Filter | < 20 s (63% response time in still air) |
Calibration Traceability | NIST and NPL standards |
Temperature |
|
Measurement Range | -40° to +70°C |
Output Resolution | 0.01°C |
Accuracy |
|
Response Time with Filter | < 120 s (63% response time in air moving at 1 m s-1) |
For this version of the CS215 Temperature and RH Probe, the cable has, instead of pigtails, a connector for attachment to the PWS100. Cable length is 1 meter.