Services Available | |
---|---|
Repair | No |
Calibration | Yes |
Free Support | No |
The CR10X-2M stored up to 1,000,000 data points.
The CR10X-2M provided sensor measurement, timekeeping, data reduction, data/program storage and control functions. Data and programs were stored either in a nonvolatile Flash memory or RAM. A lithium battery backed up the RAM and real-time clock. The CR10X-2M also suspended execution when primary power (BPALK, PS100) dropped below 9.6 V, reducing the possibility of inaccurate measurements.
Read MoreThe CR10X-2M stored up to 1,000,000 data points. The data logger consisted of a CR10XM-2M Measurement and Control Module and black CR10X Wiring Panel.
The CR10X-2M provided sensor measurement, timekeeping, data reduction, data/program storage and control functions. Data and programs were stored either in a nonvolatile Flash memory or RAM. A lithium battery backed up the RAM and real-time clock. The CR10X-2M also suspended execution when primary power (BPALK, PS100) dropped below 9.6 V, reducing the possibility of inaccurate measurements.
The CR10X-2M was removed from our pricing system on 19 April 2007.
A typical field-based CR10X-2M system included:
Execution of this download installs the CR10X Operating System (Mixed-Array) on your computer.
Note: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.
Execution of this download installs the CR10X Table Data Operating System on your computer.
Note: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.
Execution of this download installs the CR10X PakBus Operating System on your computer.
Note: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.
A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.
Supported Operating Systems:
Windows 11 or 10 (Both 32 and 64 bit)
Number of FAQs related to CR10X-2M: 9
Expand AllCollapse All
The CR10X has battery-backup RAM and clock. In other words, the program, final storage data, or clock settings are not lost if ac power is lost. Data is sent to final storage by an internal program. Data can be sent by an internal program from final storage to a storage module, computer, or printer using Instruction 96 Active Serial Data Output.
The CR1000 can send data to the Internet using GPRS.
The CR10X uses downloadable operating systems instead of PROMs and includes more instruction in the standard operating system. For a list of instructions included in the standard operating system, refer to the prompt sheet or CR10X manual.
Data can be sent out the CS/IO port automatically using Instruction 96 Activate Serial Data Output.
Instruction 15, Control Port Serial I/O, does allow the use of one control port for hardware flow control (RTS/DTR) or (TXD/RXD). The first control port is the (RTS/DTR) line. Baud rate is limited to 300 or 1200.
If the CR10X has Modbus OS, Wonderware can be used to display the data. Without the Modbus OS, LoggerNet software would be needed to collect the data and then the PC-OPC Sever software would be used to display the data.
Yes. We have created a software application, Transformer, to help migrate Edlog program files to CRBasic program files. Transformer is available within LoggerNet 3.2 and higher.
Transformer uses a CSI or DLD file created in Edlog to generate CRBasic code. A side-by-side comparison of the two programs is provided along with an action log that highlights parts of the program that may need attention or additional editing in CRBasic.
The CR510, CR500, CR10X, CR23X, CR800, CR850, CR3000, and CR1000 can be used for Modbus applications.
The CR510, CR500, and CR10X require a special operating system. Purchase an operating system with the Modbus protocol, and download it to the datalogger using CSOS downloading software or the DevConfig Utility.
Modbus protocol is standard in the CR23X, CR800, CR850, CR3000, and CR1000.
Yes. The data can be obtained directly from the CR10X using the Modbus protocol. The datalogger must have a Modbus operating system installed. The Modbus operating system can be purchased initially with the datalogger, or contact Campbell Scientific for a Modbus OS to retrofit the CR10X.
An alternate method of obtaining the data is using OPC. Our LoggerNet and PC-OPC software are needed. The version of Wonderware must also work with OPC.