The 034B-ET, manufactured by Met One, combines a three-cup anemometer and vane into a single integrated package to measure wind speed and direction. This wind set is constructed out of lightweight aluminum and is designed for continuous, long-term operation for your applications.
For this version of the 034B Wind Set, the cable terminates in a connector and is the ideal length for attachment to the ET107 or ET106 ETo Weather Station.
Read MoreThe 034B-ET monitors wind speed using a three-cup anemometer that contains a sealed magnetic reed switch. Rotation of the cup wheel produces a pulse that is directly proportional to wind speed. The frequency of the pulse is measured by the datalogger pulse count channel, then converted to engineering units (mph, m/s, knots).
Wind direction is sensed with a potentiometer. With the precision excitation voltage from the datalogger applied to the potentiometer element, the output signal is an analog voltage that is directly proportional to the azimuth of the wind direction.
Operating Temperature | -30° to +70°C |
Cable Length | 170.18 cm (67 in.) |
Weight | 907 g (2 lb) |
Wind Speed (Anemometer) |
|
Range | 0 to 75 m/s (0 to 167 mph) |
Accuracy < 10.14 m/s (22.7 mph) | 0.1 m/s (0.25 mph) |
Accuracy > 10.14 m/s (22.7 mph) | ±1.1% of true |
Resolution | (0.7998 m s-1) / (scan rate in seconds) or (1.789 mph) / (scan rate in seconds) |
Starting Threshold | 0.4 m/s (0.9 mph) |
Sensor Output | Pulsed contact closure |
Anemometer Radius | 10.7 cm (4.2 in.) |
Anemometer Height | 24.4 cm (9.6 in.) |
Wind Direction (Vane) |
|
Mechanical Range | 360° |
Electrical Range | 356° (4° open) |
Accuracy | ±4° |
Damping Ratio | 0.25 |
Resolution | < 5° |
Potentiometer Resistance | 0 to 10 kΩ (open at crossover) |
Vane Length | 33.5 cm (13.2 in.) |
The 034B-ET is a replacement part for the ET107 and ET106.
Number of FAQs related to 034B-ET: 4
Expand AllCollapse All
The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a datalogger. For other sensors, the calibration sheet is a pass/fail report.
This depends on the information contained in the calibration sheet:
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field on the product’s Ordering tab. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact an application engineer at Campbell Scientific for assistance.